<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Command and Control</title>
<title_fa>فصلنامه علمی-پژوهشی فرماندهی و کنترل</title_fa>
<short_title>C4I Journal</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://ic4i-journal.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2645-7245</journal_id_issn>
<journal_id_issn_online>2645-8055</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<volume>6</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارائه چارچوب پیشنهادی برای پایش پیوسته نرخ تجمعی شدت تشعشعات الکتریکی زیرساخت انتقال و دسترسی رادیویی در توسعه شبکه ملی اطلاعات</title_fa>
	<title>Presenting a proposed framework for continuous monitoring of the cumulative rate of electrical radiation intensity of transmission infrastructure and radio access in the development of the national information network.</title>
	<subject_fa>پدافند غیرعامل</subject_fa>
	<subject>passive defense</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;span style=&quot;font-size:12pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Lotus&amp;quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;در این مقاله موضوع پایش پیوسته شدت تشعشعات الکترومغناطیسی همزمان با توسعه زیرساخت&amp;shy;های ارتباطی رادیویی در شبکه ملی اطلاعات بررسی شده است. از جمله مهمترین اجزاء شبکه ملی اطلاعات بخش&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;&amp;shy;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Lotus&amp;quot;&quot;&gt;&lt;span style=&quot;font-weight:normal&quot;&gt;های دسترسی و انتقال رادیویی می&amp;shy;باشند. رسیدن به الزاماتی که در اسناد شبکه ملی اطلاعات به عنوان اهداف کمی ذکر شده&amp;shy;اند ناگزیر به بهره&amp;shy;برداری از شبکه نوین ارتباطات سلولی نظیر نسل پنجم شبکه&amp;shy;های ارتباطی است. شبکه&amp;shy;های نوین به دلیل چگال&amp;shy;تر &amp;nbsp;شدن ایستگاه&amp;shy;ها عملا باعث افزایش شدت تشعشعات پرتوهای رادیویی خواهند شد. از طرفی با توجه به چرخه پدافند غیر عامل زیستی، اولین حلقه از پدافند غیرعامل زیستی، پایش و رصد دائمی خطرات و تهدیدات می&amp;shy;باشد. در هیمن راستا سنجه الکتریکی برای اندازه&amp;shy;گیری شدت تشعشعات الکترومغناطیسی و مقایسه آن با سطوح مجاز بر اساس استانداردهای جهانی و ملی طراحی، شبیه&amp;shy;سازی و ساخته شد. همزمان با برنامه&amp;shy;های توسعه شبکه ملی اطلاعات و با در نظر گرفتن منشور حقوق شهروندی در بهره مندی شهروندان از بهداشت تشعشعی، ایجاد یک شبکه سراسری یکپارچه از سنجه&amp;shy;های الکتریکی برای پایش پیوسته شدت تشعشعات در کشور به عنوان یک نیاز مورد توجه قرار گرفت. مکانیابی و چیدمان صحیح محل نصب سنجه&amp;shy;های الکتریکی نیاز به تعیین شاخص&amp;shy;ها و معیارهای موثر دارد. در انتهای مقاله سه دسته شاخص&amp;shy; از منظر فنی، محیطی و اجتماعی برای انتخاب محل نصب سنجه ها شناسایی و پیشنهاد شده&amp;shy;اند. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;br&gt;
&amp;nbsp;</abstract_fa>
	<abstract>&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,serif&quot;&gt;In this article, the topic of continuous monitoring of the intensity of electromagnetic radiation simultaneously with the development of radio communication infrastructures in the national information network is investigated. Among the most important components of the National Information Network are the access and radio transmission sections. Achieving the requirements that are mentioned as quantitative goals in the documents of the National Information Network is inevitable to use the new cellular communication network such as the fifth generation of communication networks. &amp;nbsp;New networks will actually increase the intensity of radio radiation due to the denser number of stations. On the other hand, according to the cycle of non-biological defense, the first link of non-biological defense is the constant monitoring of risks and threats. In the direction of Hayman, an electric meter was designed, simulated and built to measure the intensity of electromagnetic radiation and compare it with the permitted levels based on international and national standards. &amp;nbsp;Simultaneously with the development plans of the national information network and taking into account the charter of citizens&amp;#39; rights in the benefit of citizens from radiation health, the creation of a nationwide integrated network of electric meters for the continuous monitoring of radiation intensity in the country was considered as a need. &amp;nbsp;The correct location and arrangement of the place of installation of electric meters requires the determination of effective indicators and criteria. &amp;nbsp;At the end of the article, three categories of indicators from the technical, environmental and social point of view have been identified and suggested for choosing the place of installation of gauges&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;</abstract>
	<keyword_fa>تشعشعات الکتریکی, نرخ تجمعی, شبکه ملی اطلاعات, پرتوگیری, سنجه میدان الکتریکی</keyword_fa>
	<keyword>Electric radiation, cumulative rate, national information network, radiation, electric field meter</keyword>
	<start_page>1</start_page>
	<end_page>15</end_page>
	<web_url>http://ic4i-journal.ir/browse.php?a_code=A-10-468-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>reza</first_name>
	<middle_name></middle_name>
	<last_name>bahri</last_name>
	<suffix></suffix>
	<first_name_fa>رضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بحری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>reza.bahri@itrc.ac.ir</email>
	<code>10031947532846002043</code>
	<orcid>10031947532846002043</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>ITRC</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Mahdi</first_name>
	<middle_name></middle_name>
	<last_name>Fasanghari</last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فسنقری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846002044</code>
	<orcid>10031947532846002044</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>ITRC</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Vahid</first_name>
	<middle_name></middle_name>
	<last_name>Yazdanian</last_name>
	<suffix></suffix>
	<first_name_fa>وحید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یزدانیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846002045</code>
	<orcid>10031947532846002045</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>ITRC</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
